Borehole heat exchanger calculation software

Heat exchanger calculator free for android free download. The number of gfunctions had to be increased considerably to allow this feature, and gfunctions for smaller distances had to be added. Performance analysis of borehole utube heat exchanger. In the other tube branch, the circulating heated heat transfer medium flows from the borehole base to the surface. The productivity of a deep borehole heat exchanger is strongly affected by the subsurface and its design is complex as goes beyond simple approximations. Determines the preliminary size for a shell and tube heat exchanger based on the process information provided. This numeric field contains the design volume flow rate of the ghe in m3s or gal min. Download the excel spreadsheet templates in this article to make preliminary heat exchanger design calculations. Thermal modelling and evaluation of borehole heat transfer.

Htri offers a wide range of software solutions for heat transfer equipment used by operating companies, engineering contractors, exchanger fabricators, and related industries. The software covers both innovative mphe and traditional bphe types of brazed heat exchangers. The design of a borehole system is generally carried out using commercial software, such as earth. Make an initial estimate of the overall heat transfer coefficient, u, based on. Hexact immediately identifies the right heat exchanger for your chiller, heat pump or other application. Thermal modelling and evaluation of borehole heat transfer core. Unlike other tools, ensures that the calculations are performed step by step to help in understanding the design calculations. This borehole design strategy could reduce the capital cost of the ground heat exchanger by reducing the amount of drilling required to serve a load. Seasonal high temperature heat storage with medium deep. The model is used to evaluate trt data by the parameter estimation technique. The inlet temperatures are known and outlet temperatures are to be determined. Its easy of use, short learning curve, quick calculation times and inherent databases make eed a useful tool in everyday engineering work for design of ground source heat pump system gshp and borehole thermal storage.

The fluid temperature exiting a borehole heat exchanger depends upon the shortterm and the longterm thermal response of the borehole and the ground surrounding the borehole, respectively. The total 2d grid model comprises a cylinder with a. With eri corporation this process become understandable and simple. There are many different types of heat exchangers widely used in the process industry. The borehole heat exchanger has four casings of different lengths. Among these alternatives, a borehole heat exchanger is better for storage of the thermal energy. High temperature borehole thermal energy storage the proposed system of a mdbtes 5 consists of multiple boreholes with depths of 100 m a 1,000 m. These tools can export calculated gfunction data in the form of idf files which can be loaded. Deep borehole heat exchangers dbhe are generally coaxial pipes installed in deep boreholes and has become an alternative approach to utilize geothermal energy. Numerical modelling of geothermal borehole heat exchanger systems. Available models and software for the simulation and sizing of vertical borehole heat exchangers and brine to water heat pump systems are. The borehole thermal resistance that is, the thermal resistance between the fluid in the utube and the borehole wall is both a key performance characteristic of a closedloop borehole ground heat exchanger and an important design parameter. Nov 22, 2017 plate heat exchanger, how it works working principle hvac industrial engineering phx heat transfer duration.

An alternative to ashraes design length equation for sizing. Modeling geothermal processes with comsol software. In this paper, based on the analytical method, we carried out the sensitivity analysis. Measurements and design calculations for a deep coaxial. A vertical ground heat exchanger vghe is most common because of its. Design calculations for optimising of a deep borehole heat. Comparison of four methods for borehole heat exchanger sizing. Q the rate of heat transfer between the two fluids in the heat exchanger in buthr kjhr for s. From the pipe to the borehole wall, the conductive heat transfer is dominant as in the case with ground heat transfer. The raw gfunctions are based on an borehole radius to active length ratio of. If you need asme uhx and tema mechanical design calculations, drawings and reports then the compress heat exchanger option is for you. The ufactor is defined by an expression analogous to newtons law of cooling. Multipole method to calculate borehole thermal resistances. One of the main advantages of trnsys software for the modelling and design of groundsource heat pumps is that it includes components for the calculation of building thermal loads, specific components for hvac, heat pumps and circulating pumps, modules for borehole heat exchangers and thermal storage, as well as climatic data files, which make.

The impact of different parameter estimation results on the design length of a borehole heat exchanger has received very little attention. The software gives the possibility to make choice of heat exchanging according to your individual demands. A downhole heat exchanger, dhe also called a borehole heat exchanger, bhe is a heat exchanger installed inside a borehole. The different properties zones of the borehole heat exchanger are based on the geometry of the borehole heat exchanger shown on the left side of figure 9. In this article, the ashrae method for borehole heat exchanger field. Laboratory and field studies, author remund, c p, abstractnote vertical ground heat exchangers are a common method of linking geothermal heat pump systems to the earth, and they consist of pipe installed into a borehole that is subsequently backfilled with a material that forms the heat transfer link between the pipe and earth. Optimization of the utilization of deep borehole heat. The experimental phase consisted of an earthair exchanger installation from which data were collected during hot weather cooling effect, cold weather heating effect, and mild weather performances. A method to evaluate thermal response tests on groundwaterfilled. There are several wellfield design software programs that assist designers in calculating the total required vhe lengths such as ground loop. Jun 17, 2015 this borehole design strategy could reduce the capital cost of the ground heat exchanger by reducing the amount of drilling required to serve a load.

Practical evaluation of borehole heat exchanger models in trnsys. Simulation for up to 100 years of ground loop heat exchangers to determine monthly average and peak heat pump entering and exiting fluid temperatures, as well as power consumption of the heat pump. This paper provides an indepth investigation of this problem, together with a full presentation of six data interpretation models and a comprehensive comparison of four representative sizing methods and their inter models. They are used for cooling down or heating up any process fluids, for example oil, natural gas, coolant fluids, water, steam etc.

For computing the borehole design length, softwarebased methods were more sensitive to the influence of parameter estimation results than. For a multiple borehole heat exchanger, the exiting fluid temperature also depends upon the thermal interactions between the boreholes. Pcprograms and modelling for borehole heat exchanger design. The heat exchanger calculator is based on effectiveness ntu method. Design of ground source heat pump systems thermal modelling and evaluation of boreholes. Recovery times after thermal response tests on vertical borehole heat exchangers.

The cea software solutions are designed by professional engineers and are easy to use and can work with several platforms and databases. Trt evaluation results are more accurate due to 3d modeling. A vertical ground heat exchanger vghe is most common because of its smaller environmental influence and land field requirement. An analytical method to calculate borehole fluid temperatures for timescales from minutes to decades. Using groundsource heat pump systems for heatingcooling of. When rising, the heat transfer medium always releases a portion of the accumulated heat energy to the heat transfer me. The calculation of the energy production has to be done via numerical simulation and requires information of the thermal rock properties of the rock in place. Accuracy of borehole thermal resistance calculation methods. The heat transfer from the circulating fluid to the pipe is considered mainly convective. Borehole heat exchanger field arrangement at the geothermal laboratory of the drilling, oil and gas faculty. The calculation of ground heat exchanger ghe performance is very important for predicting the performance and estimating the initial cost of geothermal heat pump systems.

The software glhepro has been making this precorrection to the data. Numerical investigation of a novel tube design for the. The superc deep borehole heat exchanger is composed of a deep borehole with an inner coaxial pipe further referred to as standpipe. Eed is a pcprogram for vertical borehole heat exchanger design. The borehole thermal resistance rb is calculated in the program, using. Thermal resistance of borehole heat exchangers composed of. It is used to capture or dissipate heat to or from the ground. The user surface shows an uptodate menu technique with pulldown menus for input parameters, control of calculation and output. Ground loop heat exchanger design software building.

The software calculates the heating and cooling energy demand of a given building on a monthly basis similar to the german calculation method used for demand based energy cer. Pdf sustainable production from borehole heat exchanger systems. The software handles for example singlephase, condenser, evaporator, cascade calculations and twostage applications. Deepborehole heat exchangers dbhe are generally coaxial pipes installed in deep boreholes and has become an alternative approach to utilize geothermal energy. Userspecified borehole configurations for up to 30 boreholes these can be vertical or inclined and irregularly placed.

Comparison of four methods for borehole heat exchanger. Correct design of vertical borehole heat exchanger systems through. The project is focusing on the heat transfer from the ground to the boreholes modelled using finite line source fls based generated gfunctions. It is easier than ever to find the right heat exchanger for your chiller, heat pump or other application. Eed borehole and heat exchanger menu with selection of gfunction example. Heat exchangers are commonly used in industry, and proper design of a heat exchanger depends on many variables. If the borehole has not been in operation earlier, it allows determining the true undisturbed ground temperature profile at each site. The heat exchanger may be composed of any number of boreholes arranged in various configurations. Borehole heat exchanger field arrangement at the geothermal laboratory of the drilling, oil and gas faculty, agh university of science and technology in cracow. Xchanger suite is software for the rating, simulation, andor design of a wide variety of heat transfer equipment. Analysis of borehole heat exchanger in an existing ground. Glhepro was developed as an aid in the design of vertical boreholetype ground loop heat exchangers used in geothermal heat pump systems. Groundsource heat pump systems use borehole heat exchangers to transfer heat to and from the ground. Simon rees, for his inspiring guidance and encouragement through my work and for the invaluable influence he has made in my academic life.

Jul 01, 2014 design of borehole heat exchangers for groundsource heat pumps. The borehole thermal resistance rb is calculated in the program, using borehole geometry. There exists many different tools used to design, size and rate heat exchangers. Heat exchanger analysis heat exchanger calculation. Therefore, we simulated the operation of a heat exchanger by setting a12 hourcycle operation running from 6. In general, multiple heat exchanger gfunctions can be calculated by spatial superposition of single ground heat exchanger analytical solutions that permit calculation of the radial temperature. Thermal resistance of utube borehole heat exchanger. The counterflow heat exchange between the pipes is also important, particularly for the axial temperature variation. In a bhe, fluid circulates through pipes that are located inside of boreholes, resulting in indirect thermal contact between the fluid and the subsurface. In the analysis of heat exchangers, it is often convenient to work with an overall heat transfer coefficient, known as a ufactor. Sizing calculation spreadsheet vertical geothermal. The temperature difference between outlet temperature and inlet temperature was set at 2 deg. Aug 10, 2011 the basic heat exchanger design equation is. While running the heat exchanger, a constant heat extraction of about 4.

Below are some of the tools and information we use on a routine basis. In north america it is estimated that on average ghe are oversized by about 10% 30%. The reliability of longterm performance of borehole heat exchanger bhe systems is now proved by numerical modelling, supported by a unique data base. Webbusterz engineering software is operated by engineer it for me ltd 7175 shelton street covent garden london. Design sizing the design of bhehp systems aims at the appropriate sizing of the system components by taking into account a number of influence factors. The heat exchanger design software covers both innovative mphe and traditional bphe types of brazed heat exchangers. Thermal efficiency of the borehole heat exchanger built with. Plate heat exchanger, how it works working principle hvac industrial engineering phx heat transfer duration.

Shell and tube heat exchanger design software for thermal. Ground loop heat exchanger tools such as glhepro and gld which are not supplied by designbuilder or energyplus are able to carry out a more detailed and accurate sizing calculation taking into account specific borehole layouts and ground properties. Heat exchanger software webbusterz engineering software. To use a borehole as a heat source, one or more holes are drilled into the ground, into which the heat transfer fluid pipe is lowered. The energyplus ground heat exchanger ghe is a condenser component. Therefore, the idea of adding longitudinal fins on the inner smooth surface of the ghes tube to ensure the better heat transfer and getting it well enhanced, as it is investigated numerically in. Out of all these types shell and tube exchangers are most popular and widely used, due to their versatility heat exchanger design calculations. Numerical study a thesis submitted to the university of manchester for the degree of master of philosophy in the faculty of engineering and physical sciences 20 raghdah alchalabi school of mechanical, aerospace and civil engineering. Fundamentals of commercial geothermal wellfield design. Proceedings of 9th international conference on sustainable energy technologies set 2010, shanghai, china.

Precise results of transient computations and short computation time. The closedloop borehole heat exchanger bhe is a standard approach for lower and middepth applications. Highlights development of a 3d numerical simulation model for utube borehole heat exchangers. Measurements in boreholes that are not in operation can furthermore be of significant help when calibrating the temperature measurement equipment. Worldwide database of time and depthvarying ground temperatures. Heat exchanger software and engineering tools, shell and tube, condenser design, kettle reboiler, plate heat exchanger, double pipe heat exchanger. In this work, the comparison of the performance of two boreholes utube models has been. Cea offers solutions to petrochemical, chemical, offshore oil and gas, pharmaceuticals, biotechnology applications, pulp and paper.

The thermal analysis of coaxial borehole heat exchanger cbhe is complicated because of the distinctive and closely interlinked heat transfer inside and outside the borehole. The contractor or design engineer has the option of either reducing the amount of drilling, while achieving the same endofseason temperature as a standard loop, or retaining the same well depth. Calculate the required heat transfer area based on values needed. Because of the limited area and lack of information on depths of ground water i have chosen to go for a closed vertical loop heat exchanger. Ground heat exchanger vertical designbuilder software ltd. Thermal response testing of a multiple borehole ground heat exchanger. Pumping power calculator heat duty calculator partial volume of tank calculator. Typical application of a borehole heat exchanger bhe heat pump hp system in a central european home. Trt duration can be shortened compared to line source evaluation.

The calculation of the energy production has to be done via numerical simulation and requires information. No matter if you have a chiller, a heat pump or a domestic hot water application, the new hexact 4th generation heat exchanger design software will allow the right heat exchanger selection by always ensuring you get the latest product range and software features at hand. Dhts are used for geothermal heating, sometimes with the help of a geothermal heat pump. The heat transfer in an earthair heat exchanger was studied in two phases to develop design criteria for these systems. Thermal resistance of utube borehole heat exchanger system. Since the performance of the dbhe system can be affected by several parameters, it is important to optimize the design of parameters for the dbhe. The fins are mainly used to enhance the heat transfer in several energy systems and one of them is the geothermal borehole heat exchanger ghe. An example of a trnys model with borehole heat exchangers and dry coolers. Pdf performance analysis of borehole utube heat exchanger. An important feature is the local thermal resistances between the heat carrier flow channels in the borehole and the surrounding ground. Accuracy of borehole thermal resistance calculation. Do you have a need for calculating plate heat exchangers. This is a software tool that allows the design of vertical borehole heat exchanger bhe fields used for heating and cooling of office buildings. Rotary, crossflow, counterflow plate heat exchanger calculation implemented by eri corporation s.

In calculation modules, the heat transfer is usually divided to be within the borehole and outside the borehole. They will also calculate the number of tubes needed for a shell and tube heat exchanger and to calculate the pipe length needed for a double pipe heat exchanger. Ssp is our unique software developed for advanced heat exchange calculations. Numerical modelling of geothermal borehole heat exchanger. What is currently the largest borehole heat exchanger system in the upper austrian provincial capital, has been supplying the office building, the ancillary buildings. Sep 23, 2009 this tutorial demonstrates how to design a commercial vertical heat exchanger system with the ground loop design software. Ever since the revitalisation of the linz branch premises in the spring of 2018, porr has placed a strong focus on renewable energy here as well. How to design a vertical borehole heat exchanger youtube. Borehole heat exchanger system porr upper austrian branch. Calculate the required heat transfer rate, q, in btuhr from specified information about fluid flow rates and temperatures. In very large and complex tasks eed allows for retrieving the. Coaxial borehole heat exchangers bhe are implemented in the boreholes. As the design is for a typical office building i have used a simple load calculator which uses rule of thumb data refer table 1to determine the load of the building with inputs being the total area and.

Provide the input data, and ssp immediately presents the product concept that meets your needs best. The basic strategy of modeling cbhe is to build respectively. The surrounding rock is utilized as a heat storage, the cementation and borehole wall function as heat exchanger. Numerical modelling of geothermal borehole heat exchanger systems iii acknowledgements i would like to express my deepest gratitude to my first supervisor, dr. Up to eight design conditions can be investigated for fixed, utube, kettle and floating tubesheet style exchangers.

1512 407 20 1327 1073 250 1334 241 863 1002 685 119 1194 356 1410 522 457 322 161 1356 98 629 1307 896 318 817 271 1310 1447 463 708 1332 1428